DMaC flowline and armoured umbilical system
DMaC flowline and armoured umbilical systems share many operational and dimensional specifications and are presented as a single system specification except for data that is obviously only relevant to either the flowline or armoured umbilical system.
Working depth 600 to 2500 metres, depending on build configuration
Installation slope tolerance +/- 5 deg.
Flowline size Up to 10 inch proven
12 to 24 inch designed
Maximum flowline length Dependant on flowline mass
Main Umbilical Connection Configuration Up to 4 electrical couplers
Up to 14 hydraulic couplers
DMaC Internal Working Pressure 5000 psig (340 bar) in service 10,000
psi designed
DMaC Connection Porch Dimensions 1.5m (w) x 1.3m (h) x 0.8m (d)
(1m between hub centres)
(1.75m between centres for 14 to 24 inch sizes)
DMaC Connection Porch weight 1.6 Tonnes
Snag Load Resistance 65 Tonnes
Bending Moment Resistance 40 Tonne metres
Torque Resistance 23.1 Tonne metres
Hub Configurations Hubs can be to a bespoke configuration with either multi-bore, single bore or control system configurations. Current models include single bore flowline from 6-inch to 10-inch and a range of multi-bore flowline hubs including 6X6X2, 8X2X2, and 6X2. Current armoured umbilical hub configuration includes 14 Hydraulic and 4 multi-pin electrical connectors.
Pullhead dimensions (typical) 3.3m (l) x 0.76m (w) x 1.7m (h)
Pullhead weight (in air) 1.5 - 2.0 Tonnes
Pull In Tool mass in air 4.5 tonnes
PIT deployment basket mass in air 3 tonnes
PIT pull in force 25 tonnes
Minimum pull in speed 1 metre / minute
Docking probes pull in force 25 tonnes
PIT winch rope capacity 150 metres of 18 mm Kevlar rope
PIT/Interface skid hydraulic connectors 32 x 1/4 inch quick disconnect
PIT/Interface skid electrical connectors 3 x 12 pin wet mateable
PIT/Interface skid mechanical connectors 15 Tonne lift capacity
DMaC ROV minimum power requirement 56 kW (75 hp)
75KW (100HP) preferred for strong current environment

 
DMaC Fly to Place System
FTP umbilical normally close to neutrally buoyant, umbilicals are deployed in a basket, and even long umbilicals over 200m can be deployed by this method.
Working depth 3000 metres
Maximum umbilical length 280+ metres
Maximum configuration 7off 1/4" hydraulic + 4off 1/2" hydraulic + 4off 9pin electrical or4off 1/4" hydraulic + 6off 1/2"hydraulic + 4off 9-pin electrical
Maximum hydraulic connector size to date 1/2"
Maximum electrical connector size to date 9-pin
Unit weights and key dimensions
Note: 3 standard plate sizes available
Type 1 Type 2 Type 3
Inboard Sizes (WxDxH) 450x582x665 540x582x665 620x582x665
Inboard Weight 75kg 85kg 94kg
Outboard Sizes (WxDxH) 353x640x1088 455x640x1088 535x640x1088
Outboard Weight 90kg 95kg 99kg
Protection Cover Sizes (WxDxH) 330x640x492 420x640x492 500x640x492
Protection Cover Weight 55kg 60kg 65kg
DMaC ROV minimum power requirement 56 kW (75 hp)
75KW (100HP) preferred for strong current environments